Introduction of water air conditioner + floor heating two-in-one system and recommendation of related thermostats

Introduction of water air conditioner + floor heating two-in-one system and recommendation of related thermostats

Introduction of water air conditioner + floor heating two-in-one system and recommendation of related thermostats

Introduction of water air conditioner + floor heating two-in-one system and recommendation of related thermostats
 
For the best-selling water air conditioner + floor heating two-in-one system on the market, I would like to bring you a little introduction.
 
Simply put, it uses a water system air conditioner (air source heat pump) host to generate hot water in winter to heat the room through the floor heating pipe; in summer, the system will generate cooling water, which is exchanged in the fan coil through the circulation system to cool the room.

  

img

 

 The air source heat pump is generally composed of four parts: compressor, condenser, evaporator and expansion valve. By controlling the components that the refrigerant in the compressor passes through, the high temperature and high pressure refrigerant first passes through the condenser to heat, and then passes through the evaporator first. Refrigeration, this is the principle that the air source heat pump can both cool and heat, but it is worth noting that the two cannot be performed at the same time.

  

img

 

  The two-in-one system has great advantages over fluorine machine air conditioners and gas wall-hung boilers:

 
1. Safety
 
The medium flowing in the pipeline of the two-in-one system is water, which has lower pressure and no pollution. The medium flowing in the air-conditioning pipeline of the fluorine machine is refrigerant, and the pressure is 15 times that of the two combined supply, and it is highly toxic. The wall-hung boiler burns natural gas, which requires high equipment safety.
 
2. Comfortable
 
The flow medium of the two-in-one system is water, and the temperature difference fluctuation is small compared to the freon medium. And it can maintain a reasonable humidity in the air, and it is not easy to get air-conditioning disease for a long time. In the winter heating season, the low temperature radiant floor heating is used, and there is no dry feeling of direct hot air.
 
3. Energy saving
 
The energy saving of the two-in-one system is mainly compared with that of the gas furnace. The combustion efficiency of the standard gas-fired wall-hung boiler is about 80%, and the combustion efficiency of the condensing wall-hung boiler can reach up to 109%, while the heating efficiency of the two-in-one system in winter is 320%. %, the excellent brand host can reach 650%.
 
We also recommend thermostats suitable for 2-in-1 systems, WIFI version: BAC-1000ALW-GA, regular version: BAC-1000AL-GA

imgimg

推荐新闻

Drahtlose thermostaten zu verstehen
Drahtlose thermostaten zu verstehen
Vier wichtige details des rasters an der wand
Vier wichtige details des rasters an der wand
Weil es das dritte thanksgiving ist
Weil es das dritte thanksgiving ist
Letzte Seite
1
2
....
9

über uns

Produktcenter

Videozentrum

Nachrichten

kontaktiere uns

Tel:+86-592-6151256

Email:sales@becaenergy.com

Add: Raum 502, 5. Stock, Gebäude Nr. 7, Lianfa Gold Industrial Park, Bezirk Tong'an, Stadt Xiamen, Provinz Fujian

beca

Öffentliches WeChat-Konto

© Xiamen Beca Energysaving Technology Co.,Ltd, . 闽ICP备2021005967号-5 Power:300.cn